Perle Essential Network Connectivity Terminal servers, Device servers, Console servers, PCI Serial Cards Secure and reliable serial connectivity solutions
 
Specialix Chase Research
Products > Advance Serial to Ethernet Technology > 8, 16, 32 or 48 Port IOLAN SCS > Technical specs
4, 8, 16 or 24 Port Secure Server
Documentation
Product and ordering information

Technical Specifications

IOLAN SCS Range

Serial Port Access
Connect directly using Telnet / SSH by port and IP address
Connect with EasyPort menu by Telnet / SSH
Use an Internet browser to access with HTTP or secure HTTPS via EasyPort Web menu
Ports can be assigned a specific IP address ( aliasing )
Multisession capability enables multiple users to access ports simultaneously
Multihost access enables multiple hosts/servers to share serial ports
Accessibility
Inband and OOB In-band ( Ethernet ) and out-of-band ( dial-up modem ) support
Optional integrated V.92 modem
GSM/GPRS Remote Wireless Access with 3rd party GSM/GPRS PC cards ( requires IOLAN PC card adapter )
Dynamic DNS enables users to find a console server from anywhere on the Internet
Domain name control through DHCP option 81
IPV6 and IPV4 addressing support
Fiber Ethernet over fiber connection using 3rd party fiber cards
Availability
Dual Ethernet - Same IP Address LAN Bonding or separate IP addresses
Primary/Backup host functionality enables automatic connections to alternate host(s)
Dual AC Power Supplies and Dual Feed 48v DC power models
Security
SSH v1 and v2
SSL V3.0/TLS V1.0, SSL V2.0
SSL Server and SSL client mode capability
SSL Peer authentication
IPSec VPN : NAT Traversal, ESP authentication protocol
Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2)
Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96
Key exchange: RSA, EDH-RSA, EDH-DSS, ADH
X.509 Certificate verification: RSA, DSA
Certificate authority (CA) list
Local database
RADIUS Authentication, Authorization and Accounting
TACACS+ Authentication, Authorization and Accounting
LDAP, NIS, Kerberos Authentication
RSA SecureID-agent or via RADIUS Authentication
SNMP v3 Authentication and Encryption support
IP Address filtering
Disable unused daemons
Terminal Server
Telnet
SSH v1 and v2
Rlogin
Auto session login
LPD, RCP printer
MOTD - Message of the day
Serial machine to Ethernet
Tunnel raw serial data across Ethernet - clear or encrypted
Raw serial data over TCP/IP
Raw serial data over UDP
Serial data control of packetized data
Share serial ports with multiple hosts/servers
Virtual modem simulates a modem connection - assign IP address by AT phone number
Virtual modem data can be sent over the Ethernet link with or without SSL encryption

TruePort com/tty redirector for serial based applications on Windows, Vista, Linux, Solaris, SCO and HP UX. For latest drivers click here
Designed for Microsoft Windows XP/2000 Certified for Windows Vista Certified for Windows Server 2008 Linux OpenServer UnixWare Solaris Ready

"TrueSerial packet technology provides the most authentic serial connections across Ethernet ensuring serial protocol integrity"
RFC 2217 standard for transport of serial data and RS232 control signals
Customizable or fixed serial baud rates
Plug-ins available for special applications
Software Development Kit ( SDK ) available
Serial encapsulation of Modbus, DNP and most other industrial protocols
ModBus TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus TCP
Data logging will store serial data received when no active TCP session and forward to network peer once session re-established - 32K bytes circular per port
Console Management
Sun Break Safe
Local port buffer viewing - 256K bytes per port
External port buffering via NFS, encrypted NFS and Syslog
Event notification
Manage AC power of external equipment using Perle RPS power management products
Clustering - central console server enables access ports across multiple console servers
Windows Server 2003/2008 EMS - SAC support GUI access to text-based Special Administrative Console
Remote Access
Dial, direct serial PPP, PAP/CHAP, SLIP
Automatic DNS Update Utilize DHCP Opt 81 to set IOLAN domain name for easy name management and with Dynamic DNS support , users on the Internet can access the device server by name without having to know its IP address. See Automatic DNS update support for details
IPSEC VPN client/servers Microsoft L2TP/IPSEC VPN client ( native to Windows XP )
Microsoft IPSEC VPN Client ( native to Windows Vista )
Cisco routers with IPSEC VPN feature set
Perle IOLAN SDS/STS and SCS models
OA&M ( Operations, Administration and Management )
SNMP V3 - read and write, Perle MIB
Syslog
Perle Device Manager - Windows based utility for large scale deployments
Configurable default configuration
Set a Personalized Factory Default for your IOLANs
Protocols
IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, SNTP, Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217

Hardware Specifications - IOLAN SCS Models - Fault Tolerant AC Rack models

 
SCS8C
SCS8C
DAC
SCS16C
SCS16C
DAC
SCS32C
SCS32C
DAC
SCS48C
SCS48C
DAC
Processor
MPC8349E, 400 Mhz, 750 MIPS
Memory
RAM MB
64
64
64
64
128
128
128
128
Flash MB
16
16
16
16
16
16
16
16
Interface Ports
Number of Serial Ports
8
8
16
16
32
32
48
48
Serial Port Interfase
RS232 DTE on RJ45
Sun / Solaris
Sun break safe
Serial Port Speeds
50bps to 230Kbps with customizable baud rate support
Data Bits
5,6,7,8, 9-bit protocol support
Parity
Odd, Even, Mark, Space, None
Flow Control
Hardware, Software, Both
Serial Port Protection
15Kv Electrostatic Discharge Protection ( ESD )
Local Console Port
RS232 on RJ45 with DB9 adapter ( provided )
Network
Dual 10/100/1000-base TX Ethernet RJ45
Software selectable Ethernet speed 10/100/1000, Auto
Software selectable Half/Full/Auto duplex
Ethernet Isolation
1.5Kv Magnetic Isolation
Integrated Modem
Optional modem card available
Integrated Wireless
Optional PC card adapter available for GSM/GPRS/3G wireless cards: Sony Ericsson PC300, Sony EricssonGC83, Sierra Wireless AirCard 881, Sierra Wireless 860
Power
Power Supply
USA models
IEC320-C13 to NEMA 5-15P line cord
UK models
IEC320-C13 to BS1363 line cord
EU models
IEC320-C13 to CEE 7/7 Schuko
South Africa Models
IEC320-C13 to BS546 line cord
Australia models
IEC320-C13 to AS3112 line cord
Redundant Power
Dual power supply
Dual power supply
Dual power supply
Dual power supply
Nominal Input Voltage
110/230v AC
Input Voltage Range
100-240v AC
AC Input Frequency
47-63Hz
Current Consumption @ 100v ( Amps )
0.17
0.20
0.18
0.21
0.19
0.22
0.2
0.23
Current Consumption @ 240v ( Amps )
0.07
0.08
0.08
0.09
0.08
0.09
0.08
0.09
Typical Power Consumption ( Watts )
17
19.5
18
20.5
19
21.5
20
22.5
Power Line Protection
Fast transients: 1 KV (EN61000-4-4 Criteria B)
Surge: 2KV (EN61000-4-5 common mode), 1KV (EN61000-4-5 differential
and common modes)
Indicators
LEDs
Power
System Ready
Network Link activity
Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output ( BTU/HR )
58
67
62
70
65
74
69
77
MTBF ( Hours )
130539
99587
122926
95094
111053
87829
115980
90884
Operating Temperature
0C to 55C, 32F to 131F
Storage Temperature
-40C to 85C, -40F to 185F
Humidity
5 to 95% (non condensing) for both storage and operation.
Case
SECC Zinc plated sheet metal (1 mm)
Ingress Protection Rating
IP30
Mounting
1U - 19" rack, front and rear mounting hardware included
Product Weight and Dimensions
Weight
3.0 kg
3.2 kg
3.1 kg
3.4 kg
3.2 kg
3.5 kg
3.5 kg
3.6 kg
Dimensions
59 x 36 x 9cm
Packaging
Shipping Dimensions
59 x 36 x 9cm
Shipping Weight
4.0 kg
4.2 kg
4.2 kg
4.4 kg
4.4 kg
4.8 kg
4.5 kg
4.9 kg
Regulatory Approvals
North America Emissions
FCC Part 15, Subpart B, Class A
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
ICES-003,Issue 4, February 2004 (Canada)
European Emissions
EN55022:1998 Class A
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker
Immunity
EN55024: 1998
EN61000-4-2: Electrostatic Discharge
EN61000-4-3: RF Electromagnetic Field Modulated
EN61000-4-4: Fast Transients
EN61000-4-5: Surge
EN61000-4-6: RF Continuous Conducted
EN61000-4-8: Power-Frequency Magnetic Field
EN61000-4-11: Voltage Dips and Voltage Interruptions
Safety
IEC 60950-1, First Edition (2001-10) and EN60950-1:2001, CB scheme.
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component)
Other
RoHS - 2002/95/EC Directive
WEEE - 2002/96/EC Directive
CCATS - G052929
ECCN - 5A992A
HTSUS Number: 8471.80.1000
Perle Lifetime warranty

IOLAN DTE

RJ45Socket

RJ45 Socket

IOLAN RJ45 Socket
Function
Direction
1
RTS
right arrow
2
DTR
right arrow
3
TXD
right arrow
4
GND
left arrow
5
GND
left arrow
6
RXD
left arrow
7
DSR
left arrow
8
CTS
left arrow

( A rolled RJ45 cable will automatically perform DTE to DCE crossover )

Optional Perle adapters for use with straight thru CAT5 cabling

Make your own cables

Part Numbers for existing customers
who want this product with traditional IOLAN pinouts

Hardware Specifications - IOLAN SCSC - Fault tolerant, 48v DC Rack, RS232 Models

 
IOLAN
SCS8C DC
IOLAN
SCS16C DC
IOLAN
SCS32C DC
IOLAN
SCS48C DC
Processor
MPC8349E, 400 Mhz, 750 MIPS
Memory
RAM MB
64
64
128
128
Flash MB
16
16
16
16
Interface Ports
Number of Serial Ports
8
16
32
48
Serial Port Interfase
RS232 DTE on RJ45
Sun / Solaris
Sun break safe
Serial Port Speeds
50bps to 230Kbps with customizable baud rate support
Data Bits
5,6,7,8, 9-bit protocol support
Parity
Odd, Even, Mark, Space, None
Flow Control
Hardware, Software, Both
Serial Port Protection
15Kv Electrostatic Discharge Protection ( ESD )
Local Console Port
RS232 on RJ45 with DB9 adapter ( provided )
Network
10/100/1000-base TX Ethernet RJ45
Software selectable Ethernet speed 10/100/1000, Auto
Software selectable Half/Full/Auto duplex
Ethernet Isolation
1.5Kv Magnetic Isolation
Integrated Modem
Integrated V.92 modem - RJ11 jack
Integrated Wireless
Optional PC card adapter available for GSM/GPRS/3G wireless cards:
Sony Ericsson PC300, Sony EricssonGC83,
Sierra Wireless AirCard 881, Sierra Wireless 860
Power
Power Supply
Dual Feed -48v DC A and B Input
Nominal Input Voltage
48 VDC
Input Voltage Range
36-72 VDC
Current Consumption @ 36v ( Amps )
0.25
0.28
0.45
0.5
Current Consumption @ 48v ( Amps )
0.19
0.21
0.34
0.38
Current Consumption @ 72v ( Amps )
0.13
0.14
0.22
0.25
Typical Power Consumption ( Watts )
9
10
16
18
Power Line Protection
Fast transients: 1 KV (EN61000-4-4 Criteria B)
Surge: 2KV (EN61000-4-5 common mode), 1KV (EN61000-4-5 differential
and common modes)
Indicators
LEDs
Power
System Ready
Network Link activity
Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output ( BTU/HR )
31
34
55
62
MTBF ( Hours )
118622
112256
94603
80743
Operating Temperature
0C to 55C, 32F to 131F
Storage Temperature
-40C to 85C, -40F to 185F
Humidity
5 to 95% (non condensing) for both storage and operation.
Case
SECC Zinc plated sheet metal (1 mm)
Ingress Protection Rating
IP30
Mounting
1U - 19" rack, front and rear mounting hardware included
Product Weight and Dimensions
Weight
3.0 kg
3.0 kg
3.2 kg
3.5 kg
Dimensions
26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in)
Packaging
Shipping Dimensions
59 x 36 x 9cm
Shipping Weight
4.0 kg
4.0 kg
4.1 kg
4.1 kg
Regulatory Approvals
North America Emissions
FCC Part 15, Subpart B, Class A
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
ICES-003,Issue 4, February 2004 (Canada)
European Emissions
EN55022:1998 Class A
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker
Immunity
EN55024: 1998
EN61000-4-2: Electrostatic Discharge
EN61000-4-3: RF Electromagnetic Field Modulated
EN61000-4-4: Fast Transients
EN61000-4-5: Surge
EN61000-4-6: RF Continuous Conducted
EN61000-4-8: Power-Frequency Magnetic Field
EN61000-4-11: Voltage Dips and Voltage Interruptions
EN 300 386
Safety
IEC 60950-1, First Edition (2001-10) and EN60950-1:2001, CB scheme.
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component)
Other
RoHS - 2002/95/EC Directive
WEEE - 2002/96/EC Directive
CCATS - G052929
ECCN - 5A992A
HTSUS Number: 8471.80.1000
Perle Lifetime warranty

IOLAN DTE

RJ45Socket

RJ45 Socket

IOLAN RJ45 Socket
Function
Direction
1
RTS
right arrow
2
DTR
right arrow
3
TXD
right arrow
4
GND
line
5
GND
line
6
RXD
larrow
7
DSR
larrow
8
CTS
larrow


( A rolled RJ45 cable will automatically perform DTE to DCE crossover )

Optional Perle adapters for use with straight thru CAT5 cabling

Make your own cables

Part Numbers for existing customers
who want this product with traditional IOLAN pinouts

Hardware Specifications - IOLAN STS Compact Models

 
4 port RS232
9-30v DC
4 port RS232
PoE - Power Over Ethernet
 
IOLAN STS4-D
IOLAN STS4-P
Processor
MPC852T, 66 Mhz, 87 MIPS
Memory
RAM MB
32
32
Flash MB
8
8
Interface Ports
Number of Serial Ports
4
4
Serial Port Interfase
RS232 DTE on RJ45
Sun / Solaris
Sun break safe
Serial Port Speeds
50bps to 230Kbps with customizable baud rate support
Data Bits
5,6,7,8, 9-bit protocol support
Parity
Odd, Even, Mark, Space, None
Flow Control
Hardware, Software, Both
Serial Port Protection
15Kv Electrostatic Discharge Protection (ESD)
Local Console Port
RS232 on RJ45 with DB9 adapter (provided)
Network
10/100-base TX Ethernet RJ45
Software selectable Ethernet speed 10/100/Auto
Software selectable Half/Full/Auto duplex
Ethernet Isolation
1.5Kv Magnetic Isolation
Power
Input Voltage Range
9 - 30v DC on barrel connector
9 - 30v DC on barrel connector
9 - 30v DC on serial RJ45 port
N/A
Barrel Connector
Dimensions are OD=5.5, ID=2.1,
length= 9.5mm
positive polarity on the inside,
negative polarity on the outside
Dimensions are OD=5.5, ID=2.1,
length= 9.5mm
positive polarity on the inside,
negative polarity on the outside
AC to DC Adapters included
USA models
NEMA 5-15P plug 110v AC to 12v DC barrel adapter
UK models
BS1363 plug 230v AC to 12v DC barrel adapter
EU models
CEE 7/7 Schuko plug 230v AC to 12v DC barrel adapter
South Africa Models
BS546 plug 230v AC to 12v DC barrel adapter
Australia models
AS3112 plug 230v AC to 12v DC barrel adapter
N/A
Power IOLAN via Serial Port
RJ45 Pin 1 on port #4
N/A
Power External Device via Serial Port
RJ45 Pin 10 on port #4,
fixed +5v DC regulated
or 9-30v DC with external adapter.
(12v DC adapter provided with unit ).
1W max
RJ45 Pin 10 on port #4,
fixed +5v DC regulated. 1W max
Power via Power over Ethernet PoE
N/A
full 802.3af Compliance
Typical Power Consumption ( Watts )
2.4
Power Line Protection
Fast transients: 1 KV (EN61000-4-4 Criteria B)
Surge: 2KV (EN61000-4-5 common mode), 1KV (EN61000-4-5 differential
and common modes)
Indicators
LEDs
Power/System Ready
Network Link activity
Serial: Transmit and Receive data per port
Environmental Specifications
MTBF ( Hours )
169753
Operating Temperature
0C to 55C, 32F to 131F
Storage Temperature
-40C to 85C, -40F to 185F
Humidity
5 to 95% (non condensing) for both storage and operation.
Ingress Protection Rating
IP30
Mounting
Wall mount - bracket included
 
DIN Rail bracket optional
Product Dimensions
Weight
0.7 kg (1.6 lbs)
Dimensions
11.3 x 8.1 x 2.8 (cm), 4.4 x 3.2 x 1.1 (in)
Regulatory Approvals
North America Emissions
FCC Part 15, Subpart B, Class A
European Emissions
EN55022:1998 Class A
Immunity
EN55024: 1998
Safety
IEC 60950-1, First Edition (2001-10) and EN60950-1:2001, CB scheme.
Other
RoHS - 2002/95/EC Directive
WEEE - 2002/96/EC Directive
CCATS - G052929
ECCN - 5A992A
HTSUS Number: 8471.80.1000
Perle Lifetime warranty

IOLAN DTE

RJ45Socket

RJ45 Socket

IOLAN RJ45 Socket
Function
Direction
1
Power In
larrow
2
DCD
larrow
3
RTS
right arrow
4
DSR
larrow
5
TXD
right arrow
6
RXD
right arrow
7
GND
line
8
CTS
larrow
9
DTR
right arrow
10
Power Out
right arrow

Optional Perle adapters for use with straight thru CAT5 cabling

Make your own cables

» Back to top

4, 8, 16 or 24 Port Secure Server Documentation Product and ordering information

 

 

Terminal Servers | Console Server | Device Server | Ethernet IO Device Server | Serial Card | About Serial to Ethernet Solutions
Site Map | Legal Information | Privacy Policy | Contact Us
Copyright © 2008 Perle. All Rights Reserved

[ International Sites ]