Products > Advance
Serial to Ethernet Technology > 8, 16, 32 or 48 Port
IOLAN SCS > Technical specs |
 |
 |
Technical Specifications
IOLAN SCS Range
| Serial Port Access |
|
Connect directly using Telnet / SSH by port and IP address |
| Connect with EasyPort menu by Telnet / SSH |
| Use an Internet
browser to access with HTTP or secure HTTPS via EasyPort Web menu |
| Ports
can be assigned a specific IP address ( aliasing ) |
| Multisession capability enables multiple users to access ports simultaneously |
| Multihost access enables multiple
hosts/servers to share serial ports |
| Accessibility |
| Inband and OOB |
In-band ( Ethernet ) and out-of-band ( dial-up modem ) support |
| Optional integrated V.92 modem |
| GSM/GPRS |
Remote Wireless Access with 3rd party GSM/GPRS PC cards ( requires IOLAN PC card adapter ) |
| Dynamic
DNS enables users to find a console server from anywhere on the Internet |
| Domain
name control through DHCP option 81 |
| IPV6 and IPV4 addressing support |
| Fiber |
Ethernet over fiber connection using 3rd party fiber cards |
| Availability |
|
Dual Ethernet - Same IP Address LAN Bonding or separate IP addresses |
| Primary/Backup host functionality enables automatic connections to
alternate host(s) |
| Dual AC Power Supplies and Dual Feed 48v DC power models |
| Security |
|
SSH v1 and v2 |
| SSL V3.0/TLS V1.0, SSL V2.0 |
| SSL Server and SSL client mode capability |
| SSL Peer authentication |
| IPSec VPN : NAT Traversal,
ESP authentication protocol |
| Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4),
ARCTWO(RC2) |
| Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96 |
| Key exchange: RSA, EDH-RSA, EDH-DSS, ADH |
| X.509 Certificate verification: RSA, DSA |
| Certificate authority (CA) list |
| Local database |
| RADIUS Authentication, Authorization and Accounting |
| TACACS+ Authentication, Authorization and Accounting |
| LDAP, NIS, Kerberos Authentication |
| RSA SecureID-agent or via RADIUS Authentication |
| SNMP v3 Authentication and Encryption support |
| IP Address filtering |
| Disable unused daemons |
| Terminal Server |
|
Telnet |
| SSH v1 and v2 |
| Rlogin |
| Auto session login |
| LPD, RCP printer |
| MOTD - Message of the day |
| Serial machine to Ethernet |
|
Tunnel raw serial data across Ethernet - clear or encrypted |
| Raw serial data over TCP/IP |
| Raw serial data over UDP |
| Serial data control of packetized data |
| Share
serial ports with multiple hosts/servers |
| Virtual modem simulates a modem connection - assign IP address by AT
phone number |
| Virtual modem data can be sent over the Ethernet link with or without
SSL encryption |
TruePort com/tty redirector for serial based applications on Windows,
Vista, Linux, Solaris, SCO and HP UX. For latest drivers click here
|
| "TrueSerial packet technology
provides the most authentic serial connections across Ethernet ensuring
serial protocol integrity" |
| RFC 2217 standard for transport of serial data and RS232 control signals |
| Customizable or fixed serial baud rates |
| Plug-ins available for special applications |
| Software Development Kit
( SDK ) available |
| Serial
encapsulation of Modbus, DNP and most other industrial protocols |
| ModBus
TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus
TCP |
| Data logging will store serial
data received when no active TCP session and forward to network peer
once session re-established - 32K bytes circular per port |
| Console Management |
|
Sun Break Safe |
| Local port buffer viewing - 256K bytes per port |
| External port buffering via NFS, encrypted NFS and Syslog |
| Event notification |
| Manage
AC power of external equipment using Perle RPS power management products |
| Clustering
- central console server enables access ports across multiple console
servers |
| Windows Server 2003/2008
EMS - SAC support GUI access to text-based Special Administrative Console |
| Remote Access |
| Dial, direct serial |
PPP, PAP/CHAP, SLIP |
| Automatic DNS Update |
Utilize DHCP Opt 81 to set IOLAN domain name for easy name management
and with Dynamic DNS support , users on the Internet can access the device
server by name without having to know its IP address. See Automatic
DNS update support for details |
| IPSEC VPN client/servers |
Microsoft L2TP/IPSEC VPN client ( native to Windows XP ) |
| Microsoft IPSEC VPN Client ( native to Windows Vista ) |
| Cisco routers with IPSEC VPN feature set |
| Perle IOLAN SDS/STS and SCS models |
| OA&M ( Operations, Administration and Management ) |
|
SNMP V3 - read and write, Perle MIB |
| Syslog |
| Perle Device Manager - Windows based utility for large scale deployments |
| Configurable default configuration |
| Set a Personalized Factory Default for your IOLANs |
Protocols |
|
IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6,
L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP,
DHCP, TFTP, SNTP, Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic
DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217 |
Hardware Specifications - IOLAN SCS Models - Fault Tolerant AC Rack models
| |
SCS8C |
SCS8C DAC |
SCS16C |
SCS16C DAC |
SCS32C |
SCS32C DAC |
SCS48C |
SCS48C DAC |
| Processor |
MPC8349E, 400 Mhz, 750 MIPS |
Memory |
| RAM MB |
64 |
64 |
64 |
64 |
128 |
128 |
128 |
128 |
| Flash MB |
|
|
|
|
|
|
|
|
Interface Ports |
| Number of Serial Ports |
8 |
8 |
16 |
16 |
32 |
32 |
48 |
48 |
| Serial Port Interfase |
RS232 DTE on RJ45 |
| Sun / Solaris |
Sun break safe |
| Serial Port Speeds |
50bps to 230Kbps with customizable
baud rate support |
Data Bits |
5,6,7,8, 9-bit protocol support |
Parity |
Odd, Even, Mark, Space, None |
Flow Control |
Hardware, Software, Both |
| Serial Port Protection |
15Kv Electrostatic Discharge Protection
( ESD ) |
| Local Console Port |
RS232 on RJ45 with DB9 adapter ( provided
) |
| Network |
Dual 10/100/1000-base TX Ethernet RJ45 |
Software selectable Ethernet speed
10/100/1000, Auto |
Software selectable Half/Full/Auto
duplex |
Ethernet Isolation |
1.5Kv Magnetic Isolation |
Integrated Modem |
Optional modem card available |
Integrated Wireless |
Optional PC card adapter available for GSM/GPRS/3G wireless cards: Sony Ericsson PC300, Sony EricssonGC83, Sierra Wireless AirCard 881, Sierra Wireless 860 |
Power |
| Power Supply |
USA models |
IEC320-C13 to NEMA 5-15P line cord |
UK models |
IEC320-C13 to BS1363 line cord |
EU models |
IEC320-C13 to CEE 7/7 Schuko |
South Africa Models |
IEC320-C13 to BS546 line cord |
Australia models |
IEC320-C13 to AS3112 line cord |
|
| Redundant Power |
|
Dual power supply |
|
Dual power supply |
|
Dual power supply |
|
Dual power supply |
| Nominal Input Voltage |
110/230v AC |
| Input Voltage Range |
100-240v AC |
| AC Input Frequency |
47-63Hz |
| Current Consumption @ 100v ( Amps ) |
0.17 |
0.20 |
0.18 |
0.21 |
0.19 |
0.22 |
0.2 |
0.23 |
| Current Consumption @ 240v ( Amps ) |
0.07 |
0.08 |
0.08 |
0.09 |
0.08 |
0.09 |
0.08 |
0.09 |
| Typical Power Consumption ( Watts ) |
17 |
19.5 |
18 |
20.5 |
19 |
21.5 |
20 |
22.5 |
Power Line Protection |
Fast transients: 1 KV (EN61000-4-4 Criteria B) |
Surge: 2KV (EN61000-4-5 common mode), 1KV (EN61000-4-5 differential
and common modes) |
Indicators |
| LEDs |
Power |
System Ready |
Network Link activity |
Serial: Transmit and Receive data per
port |
Environmental Specifications |
| Heat Output ( BTU/HR ) |
58 |
67 |
62 |
70 |
65 |
74 |
69 |
77 |
| MTBF ( Hours ) |
130539 |
99587 |
122926 |
95094 |
111053 |
87829 |
115980 |
90884 |
| Operating Temperature |
0C to 55C, 32F to 131F |
| Storage Temperature |
-40C to 85C, -40F to 185F |
| Humidity |
5 to 95% (non condensing) for both
storage and operation. |
| Case |
SECC Zinc plated sheet metal (1 mm) |
| Ingress Protection Rating |
IP30 |
| Mounting |
1U - 19" rack, front and rear
mounting hardware included |
Product Weight and Dimensions |
| Weight |
3.0 kg |
3.2 kg |
3.1 kg |
3.4 kg |
3.2 kg |
3.5 kg |
3.5 kg |
3.6 kg |
| Dimensions |
59 x 36 x 9cm |
Packaging |
| Shipping Dimensions |
59 x 36 x 9cm |
| Shipping Weight |
4.0 kg |
4.2 kg |
4.2 kg |
4.4 kg |
4.4 kg |
4.8 kg |
4.5 kg |
4.9 kg |
Regulatory Approvals |
| North America Emissions |
FCC Part 15, Subpart B, Class A |
CFR47:2003, Chapter 1, Part 15 Subpart
B,(USA) Class A |
ICES-003,Issue 4, February 2004 (Canada) |
| European Emissions |
EN55022:1998 Class A |
EN61000-3-2 : 1995, Limits for Harmonic
Current Emissions |
EN61000-3-3 : 1995, Limits of Voltage
Fluctuations and Flicker |
| Immunity |
EN55024: 1998 |
EN61000-4-2: Electrostatic Discharge |
EN61000-4-3: RF Electromagnetic Field
Modulated |
EN61000-4-4: Fast Transients |
EN61000-4-5: Surge |
EN61000-4-6: RF Continuous Conducted |
EN61000-4-8: Power-Frequency Magnetic
Field |
EN61000-4-11: Voltage Dips and Voltage
Interruptions |
| Safety |
IEC 60950-1, First Edition (2001-10)
and EN60950-1:2001, CB scheme. |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL
60950-1,
First Edition April 1st 2003 (Recognized Component) |
| Other |
RoHS - 2002/95/EC Directive |
WEEE - 2002/96/EC Directive |
CCATS - G052929 |
ECCN - 5A992A |
HTSUS Number: 8471.80.1000 |
Perle Lifetime warranty |
|
IOLAN DTE

RJ45 Socket |
IOLAN RJ45 Socket |
Function |
Direction |
1 |
RTS |
|
2 |
DTR |
|
3 |
TXD |
|
4 |
GND |
|
5 |
GND |
|
6 |
RXD |
|
7 |
DSR |
|
8 |
CTS |
|
( A rolled RJ45 cable will automatically perform DTE to DCE crossover )
Optional
Perle adapters for use with straight thru CAT5 cabling
Make
your own cables
Part Numbers for existing customers who want this product with traditional IOLAN pinouts
|
Hardware Specifications - IOLAN SCSC - Fault tolerant, 48v DC Rack, RS232 Models
| |
IOLAN SCS8C DC |
IOLAN SCS16C DC |
IOLAN SCS32C DC |
IOLAN SCS48C DC |
| Processor |
MPC8349E, 400 Mhz, 750 MIPS |
Memory |
| RAM MB |
64 |
64 |
128 |
128 |
| Flash MB |
|
|
|
|
Interface Ports |
| Number of Serial Ports |
8 |
16 |
32 |
48 |
| Serial Port Interfase |
RS232 DTE on RJ45 |
| Sun / Solaris |
Sun break safe |
| Serial Port Speeds |
50bps to 230Kbps with customizable
baud rate support |
Data Bits |
5,6,7,8, 9-bit protocol support |
Parity |
Odd, Even, Mark, Space, None |
Flow Control |
Hardware, Software, Both |
| Serial Port Protection |
15Kv Electrostatic Discharge Protection
( ESD ) |
| Local Console Port |
RS232 on RJ45 with DB9 adapter ( provided
) |
| Network |
10/100/1000-base TX Ethernet RJ45 |
Software selectable Ethernet speed
10/100/1000, Auto |
Software selectable Half/Full/Auto
duplex |
| Ethernet Isolation |
1.5Kv Magnetic Isolation |
| Integrated Modem |
Integrated V.92 modem - RJ11 jack |
| Integrated Wireless |
Optional PC card adapter available for GSM/GPRS/3G wireless cards: Sony Ericsson PC300, Sony EricssonGC83, Sierra Wireless AirCard 881, Sierra Wireless 860
|
Power |
| Power Supply |
Dual Feed -48v DC A and B Input |
| Nominal Input Voltage |
48 VDC |
| Input Voltage Range |
36-72 VDC |
| Current Consumption @ 36v ( Amps ) |
0.25 |
0.28 |
0.45 |
0.5 |
| Current Consumption @ 48v ( Amps ) |
0.19 |
0.21 |
0.34 |
0.38 |
| Current Consumption @ 72v ( Amps ) |
0.13 |
0.14 |
0.22 |
0.25 |
| Typical Power Consumption ( Watts ) |
9 |
10 |
16 |
18 |
Power Line Protection |
Fast transients: 1 KV (EN61000-4-4 Criteria B) |
Surge: 2KV (EN61000-4-5 common mode), 1KV (EN61000-4-5 differential
and common modes) |
Indicators |
| LEDs |
Power |
System Ready |
Network Link activity |
Serial: Transmit and Receive data per
port |
Environmental Specifications |
| Heat Output ( BTU/HR ) |
31 |
34 |
55 |
62 |
| MTBF ( Hours ) |
118622 |
112256 |
94603 |
80743 |
| Operating Temperature |
0C to 55C, 32F to 131F |
| Storage Temperature |
-40C to 85C, -40F to 185F |
| Humidity |
5 to 95% (non condensing) for both
storage and operation. |
| Case |
SECC Zinc plated sheet metal (1 mm) |
| Ingress Protection Rating |
IP30 |
| Mounting |
1U - 19" rack, front and rear
mounting hardware included |
Product Weight and Dimensions |
| Weight |
3.0 kg |
3.0 kg |
3.2 kg |
3.5 kg |
| Dimensions |
26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in) |
Packaging |
| Shipping Dimensions |
59 x 36 x 9cm |
| Shipping Weight |
4.0 kg |
4.0 kg |
4.1 kg |
4.1 kg |
Regulatory Approvals |
| North America Emissions |
FCC Part 15, Subpart B, Class A |
CFR47:2003, Chapter 1, Part 15 Subpart
B,(USA) Class A |
ICES-003,Issue 4, February 2004 (Canada) |
| European Emissions |
EN55022:1998 Class A |
EN61000-3-2 : 1995, Limits for Harmonic
Current Emissions |
EN61000-3-3 : 1995, Limits of Voltage
Fluctuations and Flicker |
| Immunity |
EN55024: 1998 |
EN61000-4-2: Electrostatic Discharge |
EN61000-4-3: RF Electromagnetic Field
Modulated |
EN61000-4-4: Fast Transients |
EN61000-4-5: Surge |
EN61000-4-6: RF Continuous Conducted |
EN61000-4-8: Power-Frequency Magnetic
Field |
EN61000-4-11: Voltage Dips and Voltage
Interruptions |
EN 300 386 |
| Safety |
IEC 60950-1, First Edition (2001-10)
and EN60950-1:2001, CB scheme. |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL
60950-1,
First Edition April 1st 2003 (Recognized Component) |
| Other |
RoHS - 2002/95/EC Directive |
WEEE - 2002/96/EC Directive |
CCATS - G052929 |
ECCN - 5A992A |
HTSUS Number: 8471.80.1000 |
Perle Lifetime warranty |
|
IOLAN DTE
RJ45 Socket |
IOLAN RJ45 Socket |
Function |
Direction |
1 |
RTS |
|
2 |
DTR |
|
3 |
TXD |
|
4 |
GND |
|
5 |
GND |
|
6 |
RXD |
|
7 |
DSR |
|
8 |
CTS |
|
( A rolled RJ45 cable will automatically perform DTE to DCE crossover )
Optional
Perle adapters for use with straight thru CAT5 cabling
Make
your own cables
Part Numbers for existing customers who want this product with traditional IOLAN pinouts
|
Hardware Specifications - IOLAN STS Compact Models
| |
4 port RS232
9-30v DC |
4 port RS232
PoE - Power Over Ethernet |
| |
IOLAN STS4-D |
IOLAN STS4-P |
| Processor |
MPC852T, 66 Mhz, 87 MIPS |
Memory |
| RAM MB |
32 |
32 |
| Flash MB |
8 |
8 |
Interface Ports |
| Number of Serial Ports |
4 |
4 |
| Serial Port Interfase |
RS232 DTE on RJ45 |
| Sun / Solaris |
Sun break safe |
| Serial Port Speeds |
50bps to 230Kbps
with customizable baud rate support |
Data Bits |
5,6,7,8, 9-bit protocol support |
Parity |
Odd, Even, Mark, Space, None |
Flow Control |
Hardware, Software, Both |
| Serial Port Protection |
15Kv Electrostatic Discharge
Protection (ESD) |
| Local Console Port |
RS232 on RJ45
with DB9 adapter (provided) |
| Network |
10/100-base TX Ethernet RJ45 |
Software selectable
Ethernet speed 10/100/Auto |
Software selectable
Half/Full/Auto duplex |
Ethernet Isolation |
1.5Kv Magnetic Isolation |
Power |
| Input Voltage Range |
9 - 30v DC on barrel connector |
9 - 30v DC on barrel connector |
9 - 30v DC on serial RJ45 port |
N/A |
| Barrel Connector |
Dimensions are OD=5.5, ID=2.1,
length= 9.5mm
positive polarity on the inside,
negative polarity on the outside |
Dimensions are OD=5.5, ID=2.1,
length= 9.5mm
positive polarity on the inside,
negative polarity on the outside |
| AC to DC Adapters included |
USA models |
NEMA 5-15P plug 110v AC to 12v
DC barrel adapter |
UK models |
BS1363 plug 230v AC to 12v DC
barrel adapter |
EU models |
CEE 7/7 Schuko plug 230v
AC to 12v DC barrel adapter |
South Africa Models |
BS546 plug 230v AC to 12v
DC barrel adapter |
Australia models |
AS3112 plug 230v AC to 12v
DC barrel adapter |
|
|
| Power IOLAN via Serial Port |
RJ45 Pin 1 on port #4 |
N/A |
| Power External Device via Serial Port |
RJ45 Pin 10 on port #4,
fixed +5v DC regulated
or 9-30v DC with external adapter.
(12v DC adapter provided with unit ).
1W max |
RJ45 Pin 10 on port #4,
fixed +5v DC regulated. 1W max |
| Power via Power over Ethernet PoE |
N/A |
full 802.3af Compliance |
| Typical Power Consumption ( Watts ) |
2.4 |
Power Line Protection |
Fast transients: 1 KV (EN61000-4-4 Criteria B) |
Surge: 2KV (EN61000-4-5 common mode), 1KV (EN61000-4-5 differential
and common modes) |
Indicators |
LEDs |
Power/System Ready |
Network Link activity |
Serial: Transmit and Receive
data per port |
Environmental Specifications |
| MTBF ( Hours ) |
169753 |
| Operating Temperature |
0C to 55C, 32F to 131F |
| Storage Temperature |
-40C to 85C, -40F to 185F |
| Humidity |
5 to 95% (non condensing)
for both storage and operation. |
| Ingress Protection Rating |
IP30 |
| Mounting |
Wall mount - bracket included |
| |
DIN Rail bracket optional |
Product Dimensions |
| Weight |
0.7 kg (1.6 lbs) |
| Dimensions |
11.3 x 8.1 x 2.8 (cm), 4.4 x 3.2 x
1.1 (in) |
Regulatory Approvals |
| North America Emissions |
FCC Part 15, Subpart B, Class A |
| European Emissions |
EN55022:1998 Class A |
| Immunity |
EN55024: 1998 |
| Safety |
IEC 60950-1, First Edition (2001-10)
and EN60950-1:2001, CB scheme. |
| Other |
RoHS - 2002/95/EC Directive |
WEEE - 2002/96/EC Directive |
CCATS - G052929 |
ECCN - 5A992A |
HTSUS Number: 8471.80.1000 |
Perle Lifetime warranty |
|
IOLAN DTE

RJ45 Socket
|
IOLAN RJ45 Socket |
Function |
Direction |
1 |
Power In |
|
2 |
DCD |
|
3 |
RTS |
|
4 |
DSR |
|
5 |
TXD |
|
6 |
RXD |
|
7 |
GND |
|
8 |
CTS |
|
9 |
DTR |
|
10 |
Power Out |
|
Optional
Perle adapters for use with straight thru CAT5 cabling
Make
your own cables
|
» Back
to top
|
| |