| Perle
LinkStream 2000
Declaration of Conformity
Route to Compliance Verification
We, Chase Research Ltd, whose registered
office is at:
3 Wintersells Road, Byfleet, Surrey KT14 7LF.
Declare under our sole responsibility that
the products
LKS2022/X21 (42282005)
LKS2022/V24 (42282105)
LKS2022/V35 (42282205)
LKS-BRI (42272115)
LKS-8A (42290005)
In accordance with the following Directives:
73/23/EEC The Low Voltage Directive and
its amending directives
89/336/EEC The Electromagnetic Compatibility Directive and
its amending directives
has been designed and manufactured
to the following specifications:
| Std Type |
Test Name |
Test Reference |
Year |
| 50081-1 |
Radiated, electric field emissions
Conducted voltage at AC port Emissions |
55022 Class A
55022 Class A |
1994
1994 |
| 50082-1 |
Electrostatic discharge immunity tests.
Radiated, radio-frequency, electromagnetic field immunity
tests
Electrical fast transient/burst, AC port
Electrical fast transient/burst, signal and control |
IEC 801-2
IEC 801-3
IEC 801-4
IEC 801-4 |
1994
1994
1998
1998 |
| Low Voltage |
Low Voltage Electrical Equipment |
EN60950 |
1997 |
| Directive 73/23/EEC |
(Safety) |
IEC 950 |
1996 |
We hereby declare that the equipment named above
has been designed to comply with the relevant sections of the
above referenced specifications. The unit complies with all
essential requirements of the Directives.
Done at Hursley EMC Services Ltd, Hampshire,
England. On the 24th November 1999.
Report Reference: Hursley EMC, Report No. 99J467CR. To EN55022:1998
Class A. EN50082-1: 1997.
Safety testing carried out by BSI Testing to IEC950:1996. EN60950:1996.
Report Reference:222-4068995.
Approved by:
John Feeney, Chief Operating Officer
Signed

|